Szolgáltatási idő: Hétfőtől péntekig 9:00-18:00
UST4C12EX - UST4C12EX ST4-C12EX PANASONIC Controller for ST4, high functional type
Raktáron Forró termék

UST4C12EX

UST4C12EX ST4-C12EX PANASONIC Controller for ST4, high functional type

$0.00 USD
4319 raktáron
Főbb specifikációk
Tétel: Specifications
PFHD: Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD: More than 100 years (Note:Mean time to dangerous failure (in years))
Súly: Net weight: 240 g approxGross weight: 450 g approx
Beszállítói információk
PANASONIC
PANASONIC
Termékek: 4316
Általában 2-3 munkanapon belül szállítjuk
Minőség garantált
Gyors szállítás
Műszaki támogatás

Műszaki adatok

Paraméter Érték
Tétel Specifications
PFHD Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD More than 100 years (Note:Mean time to dangerous failure (in years))
Súly Net weight: 240 g approxGross weight: 450 g approx
Részletek Controller [High-functional]
Termék Compact Type 4 Safety Beam Sensor
Anyag Enclosure: ABS
Cikkszám ST4-C12EX
Termék neve Compact Type 4 Safety Beam Sensor ST4
Kábelkábel Terminal block connector: 0.2 to 1.5 mm2Power supply connector (A1, A2): 0.2 to 2.5 mm2
Tápfeszültség 24 V DC +10-15 % Ripple P-P 10 % or less
Válaszidő OFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
Termékszám ST4-C12EX
Segédkimenetek PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Némítólámpa kimenet Available muting lamp: 24 V DC, 1 to 10 W(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Csatlakozó terminál Detachable spring-cage terminal
Áramfogyasztás 120 mA or less (excluding sensor head ST4-Ax)
Alkalmazandó szabványok IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Alkalmazható érzékelőfej ST4-Ax
CE-jelölési irányelvnek való megfelelés Machinery Directive, EMC Directive, RoHS Directive
Segédkimenetek: Üzemmód ON when muting function is invalidOFF when muting function is validON when override function is invalidOFF when override function is validON when muting lamp is in normal conditionOFF when muting lamp is in abnormal conditionNegative logic of the control outputs (OSSD1, OSSD2)
Vezérlő kimenetek (OSSD 1, OSSD 2) PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Segédkimenetek: Védőáramkör Incorporated
Némító lámpa kimenet: Védő áramkör Incorporated
Környezeti ellenállás: Környezeti páratartalom 30 to 85 % RH, Storage: 30 to 95 % RH
Környezeti ellenállás: Ütésállóság 300 m/s2acceleration in X, Y and Z directions three times each
Környezeti ellenállás: Környezeti hőmérséklet -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Környezeti ellenállás: Védettségi fok Enclosure: IP40 (IEC)Terminal: IP20 (IEC)
Környezeti ellenállás: Rezgésállóság 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Környezeti ellenállás: Szigetelési ellenállás 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Vezérlő kimenetek (OSSD 1, OSSD 2): Üzemmód ON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interrupted(except during muting / override)OFF during lockout
Alkalmazható érzékelőfej: Soros csatlakozások száma Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Vezérlő kimenetek (OSSD1, OSSD2): Védő áramkör Incorporated
Környezeti ellenállás: Feszültségállóság 1,000 V AC for one min. between all supply terminals connected together and enclosure

Termékleírás

ST4 Series High Functionality Control Unit
Főbb jellemzők
  • Ipari minőségű
  • RoHS-kompatibilis
  • CE minősítésű
  • 1 év garancia

Termékdokumentumok

Adatlap

Műszaki adatok és teljesítményadatok

Felhasználói kézikönyv

Telepítési és üzemeltetési útmutató