| Paraméter | Érték |
|---|---|
| Tétel | Specifications |
| Kábel | 5-core composite cable, 2 m6.5617 ftlong |
| Súly | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) |
| Részletek | Measurement center 400mm 15.748 in type |
| Termék | CMOS type Micro Laser Distance Sensor |
| Anyag | Enclosure: Aluminum die-castFront cover: Acrylic |
| Linearitás | ±0.2 % F.S. (Measuring distance 200 to 400 mm7.874 to 15.748 in)±0.3 % F.S. (Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Védelem | IP67 (IEC) |
| Cikkszám | HG-C1400 |
| Fényforrás | Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note) ]Max. output: 1 mWemission peak wavelength: 655 nm0.026 mil(Note) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Termék neve | CMOS type Micro Laser Distance Sensor HG-C |
| Gerenda átmérője | ø500 μm19.6851 milapprox.(Note) This is the size in the measurement center distance. These values were defined by using 1/e2(13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. |
| Ismételhetőség | 300 μm11.811 mil(Measuring distance 200 to 400 mm7.874 to 15.748 in)800 μm31.496 mil(Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Válaszidő | Switchable between 1.5 ms / 5 ms / 10 ms |
| Szabályozó kimenet | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 30 V DC or less (Between control output to 0V)- Residual voltage: 1.5 V or less (At 50 mA sink current)- Leakage current: 0.1 mA or less |
| Külső bemenet | NPN non-contact input- Input conditionsInvalid: +8 to +V DC or OpenValid: 0 to +1.2 V DC- Input impedance: 10 kΩ approx. |
| Termékszám | HG-C1400 |
| Tápfeszültség | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less |
| Kábelhosszabbító | Extension up to total 10 m393.701 ftis possible with 0.3 mm2, or more, cable. |
| Mérési tartomány | ±200 mm7.874 in |
| Környezeti páratartalom | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Szennyezettségi fok | 2 |
| Ütésállóság | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Üzemeltetési magasság | 2,000 m6561.680 ftor less |
| Környezeti megvilágítás | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Környezeti hőmérséklet | -10 to +45 ℃-14 to 113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to 140 ℉ |
| Áramfogyasztás | 40 mA or less (at 24V DC supply voltage)65 mA or less (at 12V DC supply voltage)Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) |
| Rezgésállóság | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Mérési középpont távolsága | 400 mm15.748 in |
| Hőmérsékleti jellemzők | 0.03% F.S./℃ |
| Vezérlő kimenet: Kimeneti működés | Either Light-ON or Dark-ON |
| Analóg kimenet: Analóg áramkimenet | • Output range: 4 to 20mA (at alarm: 0mA)• Output impedance: 300Ω or lessNote : Analog current output has been added from shipment in August 2016. |
| Analóg kimenet: Analóg feszültségkimenet | • Output range: 0 to 5 V (at alarm: +5.2 V)• Output impedance: 100Ω |
| Vezérlő kimenet: Rövidzárlatvédelem | Incorporated (Auto reset type) |
| Alkalmazandó előírások és tanúsítványok | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification(Note) : The UL/c-UL certified products have been shipped since April, 2017. |
Műszaki adatok és teljesítményadatok
Telepítési és üzemeltetési útmutató