HC-K 6/12-ESTS - HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert
Raktáron Forró termék

HC-K 6/12-ESTS

HC-K 6/12-ESTS 1636350 PHOENIX CONTACT Contact insert

$114.79 USD
128 raktáron
Főbb specifikációk
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Típus: B16
Szélesség: 34 mm
Magasság: 47.2 mm
Beszállítói információk
Termékek: 0
Általában 2-3 munkanapon belül szállítjuk
Minőség garantált
Gyors szállítás
Műszaki támogatás

Műszaki adatok

Paraméter Érték
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Típus B16
Szélesség 34 mm
Magasság 47.2 mm
Hossz 84.5 mm
Sorozat HC-K
Általános For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
Alkalmazás Power/signal
Terméktípus Contact insert with a fixed no. of positions
Összeszerelési megjegyzés To ensure correct use, installation in housing with IP54 protection or better is required
Névleges áram 40 A (power contacts)
Cikk felülvizsgálata 04
Érintkező átmérője 4 mm
Érintkező anyag Cu alloy
Telefonszámozás 1 - 6 (power contacts)
Csavarhúzó penge 0.5 x 3.5 mm (control contacts)
Meghúzási nyomaték 2 Nm ... 2.5 Nm (PE connection)
Csatlakozási profil 6+12+PE
A szennyezettség mértéke 3
Méretrajz
Pozíciók száma 18
Névleges túlfeszültség 8 kV (power contacts)
Túlfeszültség kategória III
Csatlakozási technológia Axial screw connection (power contacts)
Érintkező anyag típusa turned
Erősáramú érintkezők száma 6
Névleges feszültség (III/3) 690 V
Vezető keresztmetszete 2.5 mm² ... 10 mm² (power contacts)
Vezérlőérintkezők száma 12
Érintkezőhordozó anyag PC
Behelyezési/kivételi ciklusok ≥ 500
Csatlakozási keresztmetszet AWG 12 ... 8 (power contacts)
Környezeti hőmérséklet (üzemi) -40 °C ... 125 °C
Fúrt furat távolsága, vízszintes 77.5 mm
Névleges feszültség a teljesítményérintkezőkhöz 230/400 V
Gyúlékonysági besorolás az UL 94 szabvány szerint V0
Az egyes vezetékek csupaszítási hossza 8 mm +1 mm (Power 6 mm² ... 10 mm²)
Érintkezőfelület anyaga, teljesítményérintkező Ag
Érintkezőfelület anyaga, vezérlőérintkező Ag

Termékleírás

Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Male, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal
Főbb jellemzők
  • Ipari minőségű
  • RoHS-kompatibilis
  • CE minősítésű
  • 1 év garancia