Főbb specifikációk
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Típus: D7
Tesztek: DIN VDE 0627/86
Szélesség: 21 mm
Beszállítói információk
Termékek: 0
Általában 2-3 munkanapon belül szállítjuk
Minőség garantált
Gyors szállítás
Műszaki támogatás

Műszaki adatok

Paraméter Érték
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Típus D7
Tesztek DIN VDE 0627/86
Szélesség 21 mm
Magasság 34.8 mm
Hossz 21 mm
Sorozat HC-HS
Általános for HC-D7 housing, axial connection 2.0 mm, Allen key
Alkalmazás Power
Terméktípus Contact insert with a fixed no. of positions
Összeszerelési megjegyzés To ensure correct use, installation in housing with IP54 protection or better is required
Névleges áram 40 A
Cikk felülvizsgálata 04
Érintkező átmérője 4 mm
Érintkező anyag Copper alloy
Hatszögletű foglalat SW2,0
Telefonszámozás 1 - 2
Meghúzási nyomaték 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Csatlakozási profil 2+PE
A szennyezettség mértéke 3
Méretrajz
Pozíciók száma 2
Névleges túlfeszültség 6 kV
Túlfeszültség kategória III
Csatlakozási technológia Axial screw connection
Érintkező anyag típusa turned
Erősáramú érintkezők száma 2
Névleges feszültség (III/3) 400 V
Vezető keresztmetszete 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Érintkezőhordozó anyag PC
Érintkező felület anyaga Ag
Behelyezési/kivételi ciklusok ≥ 500
Csatlakozási keresztmetszet AWG 10 ... 8
Környezeti hőmérséklet (üzemi) -40 °C ... 125 °C (including heating up of contacts)
Csatlakozás a szabvány szerint IEC / EN
Építési és vizsgálati előírások DIN VDE 0627/86
Gyúlékonysági besorolás az UL 94 szabvány szerint V0
Az egyes vezetékek csupaszítási hossza 8 mm +1 mm

Termékleírás

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Főbb jellemzők
  • Ipari minőségű
  • RoHS-kompatibilis
  • CE minősítésű
  • 1 év garancia

Termékdokumentumok

Adatlap

Műszaki adatok és teljesítményadatok

Felhasználói kézikönyv

Telepítési és üzemeltetési útmutató

Top